📋findingenergy
Electricity consumption exceeds industry benchmark
The specific electricity consumption of 185 kWh/m² is 23% higher than the industry average of 150 kWh/m² for similar manufacturing facilities.
AI Confidence:
89%
Source: Energy Data Analysis
Validated
⚠️gapprocesses
Missing compressed air system data
No consumption data available for compressed air systems. Based on industry patterns, this could represent 15-25% of process electricity consumption.
AI Confidence:
65%
Source: Data Completeness Check
Flagged
📋findingbuildings
Heating system efficiency below rated performance
The main gas boiler shows an operational efficiency of 82%, significantly below its rated efficiency of 95%. This suggests maintenance issues or improper sizing.
AI Confidence:
75%
Source: Building Systems Analysis
Rejected
🔍anomalyenergy
Unusual consumption spike in August
Energy consumption in August was 40% higher than the monthly average despite reduced production. This may indicate equipment malfunction or data recording error.
AI Confidence:
92%
Source: Statistical Analysis
Validated